It is an important part of dental restoration equipment, mainly used for grinding, polishing and cleaning in the process of denture restoration.
The laboratory handpiece is also called the micro-mechanical grinder. It is used for grinding, cutting and grinding when making dentures. The machine has the characteristics of small size, high speed, strong cutting force, stable and reliable rotation, and easy to carry.
As a professional wholesale dental supply company, we also provide electric wax knife dental, Gypsum Settling Basin, dental lab workstations, etc.
Nearly all dental lab handpieces need a dental lab micromotor for power in drilling semihard tissues in the mouth. In everyday dentistry practice, the dental lab micromotor controls both the torque and the speed level of the dental lab micromotor handpiece. The dental lab high speed handpiece serves as a precision device which can remove tooth tissue efficiently and rapidly with no pressure, heat or vibration and cut the tooth like butter. The high-speed micromotor dental handpiece rotates the bur / rotary cutting tool at speeds between 200k rpm and 450k rpm, hence it is named high-speed!
The dental lab micromotor is used for the semihard dental tissues treatment, mainly polishes and trims teeth for patients in dentistry. Dental lab micromotor is connected to the hoses of the dental technician tools with a variable connection system. The micromotor laboratorio dental rotates the polishing cup or micromotor burs from 0 to 35,000 rpm and even enables to go in clockwise or anti-clockwise direction, as long as the user requires. The speed and torque of dental lab micro motors are also variable. And, two different types of instruments (handpiece and contra-angle) can be placed on the dental lab handpiece motor.
Dental Lab Micromotor Advantages
The dental lab micromotor is composed of high torque, which means that the dental Lab micromotor handpiece can also increase speed. Dentists can easily adjust the micromotor dental handpiece through the interchangeable head of the micromotor. Dental laboratory micromotor equipment is very inexpensive and competitive compared to other lab micromotor equipment used in oral care. In addition, the dental lab micromotor is light and powerful, so your instrument does not require additional power.
Dental Lab Micromotor Disadvantages
Dental lab handpiece is able to heat up and vibrate after prolonged use. Brushless motors on dental prosthodontics can be difficult to manage. Mostly, dentists have to buy two tiny motors with different speeds. The dental lab micro motor machine can be very slow or very fast and difficult to manage polished and cut tissue in the mouth.
Any kind of mechanical equipment needs our careful maintenance to reduce its failure rate and prolong its service life. The maintenance of dental micromotors is a regular job. The quality of maintenance work directly affects the operation rate and service life of the electric motor. Appropriately handle and arrange intermediate and major repair plans according to the priority of the defects.
Micro motor used in dentistry is easy to clean and maintain after using. Lab handpieces, turbines and dental lab micromotors must be sterilised and disinfected to prevent the spread of bacterial and viral infections. In addition, you can maintain these parts by carefully separating them and sterilizing them with autoclaves. When using lab micromotors in dental offices, safety and precaution are a must.
1. There are two steps to sterilize the drill bit of the dental micromotor: one is to clean the drill bit. After completing a job, dust and man-made contamination should be removed with a metal brush. The second is disinfection. Immerse the drill bit in the disinfectant, take it out after soaking for a period of time as required, dry it, and store it in a clean and dry disinfectant container. The polishing bit can be hand washed and then put in the dishwasher for a good drying effect.
2. Replace the drill bit. When the drill bit needs to be replaced depends on the frequency of use of the drill bit and the quality of the drill bit itself. If you feel that the grinding powder is small, you should add some force, which can generate more pressure, and then it is time to replace the drill. A good quality drill can last for several months even with frequent use. Buying a good quality drill will save you money in the long run. If you drop the handle holding the drill on the ground, throw the drill away immediately. Because if the bit holder is bent, the bit is also bent, which will affect the grinding effect.
3. The lifespan of the dental micromotor depends on its usage and regular maintenance. The quality of the dental micromotor is also a factor in his longevity. If properly maintained, the average motor can last for several years. The most important and most expensive part is the handle, which cost more than 3/4 of the cost of the whole device. If the noise of the motor handle is getting louder and louder, it means that the dental micromotor needs repair and maintenance.
4. Maintenance of the dental micromotor, the maintenance cost is generally affected by many factors, including the model and the degree of wear and tear. And every year, the manufacturer will professionally clean the grinder. Proper maintenance can extend the life of your dental micromotor and keep it working properly.
Precautions for use
1. The handle must not be idling, and the bur must be installed.
2. It is strictly forbidden to use non-original accessories.
3. Strong collision is strictly prohibited, especially the handle mouth, the most afraid of falling straight to the ground.
4. It is strictly forbidden to refuel the bearing.
5. Keep a safe distance that children cannot touch.
6. Please keep the environment clean.
7. Do not overload the machine.
8. To prevent accidental start.
9. Determine the voltage and volts of the socket.
10. After the product is started, do not touch it with your hands.
11. Please keep away from water and fire.
12. Use goggles to prevent dust from being sprayed into your eyes.
13. The grinding head will gradually wear out. At this time, please remove the old grinding head and replace it with a new one.
14. Please be sure to turn off the power when not in use for safety.
JD5500 Dental Lab Micromotor Parameter
Model: | JD5500 |
Voltage: | 100V-110V/220V-240V |
Cycle: | 50-60 HZ |
Electric power: | 85W |
Weight: | 1850 g |
Dimension: | 74*165*192mm |
Color | Gray |
Speed: | 0-35000 RPM.MAX |
MAX. Torque: | 4.8 N cm |
Weight: | 213 g |
35000RPM Speed Adjustable
1. Carbon Brush Micromotor.
2. Forward reverse selection switching delay of 2 seconds protects the motor effectively.
3. Automatic overload protection of the microcomputer can protect safety of both the operator and the machine
4.R.P.M can be controlled by hand or Foot/knee using Hand/foot Pedal.
5.No noise, vibration or heat after long hours of operation, ensuring smooth operation.
6.Standard accessory: Micromotor Handpiece, control box, Foot pedal
The Details Of JD5500 Dental Lab Micromotor
JD7500 Dental Lab Micromotor Handpiece Parameter
Model: | JD7500 |
Voltage: | 100V-120V/220V-240V |
Cycle: | 50-60 HZ |
Electric power: | 65W |
Weight: | 1450 g |
Dimension: | 135*132*85mm |
Color | Black |
Speed: | 0-35000 RPM.MAX |
MAX. Torque: | 4.7N cm/7.0Ncm |
Weight: | 213 g |
JD7500 Micromotor Dental Handpiece Features
Variable speed control by hand dial or foot pedal
Round Cradle for handpiece mounted inside controller
No heat after long hours of operation by effective electrical design.
Automatic safety overload protection system
Standard accessory: Micromotor Handpiece, control box, Foot pedal
How To Change The Grinding Head By Hand
JD8500 Micromotor Dental Handpiece Parameter
Model: | JD8500 |
Voltage: | 100V-120V/220V-240V |
Cycle: | 50-60 HZ |
Electric power: | 65W |
Weight: | 1250 g |
Dimension: | 120*280*81mm |
Color | Pink & Grey |
JD8500 Lab Micromotor Features
35000RPM Speed adjustable
Carbon Brush Micromotor.
Variable speed control by hand dial or foot pedal
Automatic safety overload protection system
Standard accessory: Micromotor Handpiece, control box, Foot pedal
Feature Of 90-102L Dental Micromotor Handpiece
Basic model, Mini-compact design
0~35,000 rpm, less-vibration standard carbon brush motor
Non stage speed system
Right/Left turning ability
On/Off switch
As the basic model among the STRONG series, heat and
vibration is minimized even for a long-time use, due to the
stable circuit layout.
Power Supply Of 90-102L Dental Lab Micromotor Handpiece
1) 220V/50HZ, Europe or international standard power plug
2) 110V/60HZ, America power plug
Feature of 204-102L Lab Micromotor
Under-sized compact design
0~35,000rpm, less-vibration standard carbon brush motor
Non stage speed system
Right/Left turning ability
On/Off switch
Basic model, is reduced heat and vibration problem for a
long-time use, due to the stable circuit layout.
Power Supply of 204-102L Dental Micromotor Handpiece
220V/50HZ, Europe or international standard power plug
Remark:
1) 90 motor is in metal cover. 204 motor is in plastic cover.
2) The two model is made in south Korea .
Feature of 207B-107 Lab Micromotor
Rated Speed: 0~40,000rpm
Rated Power: 65W
Torque: 300gf.cm
Variable speed control by hand dial or foot pedal
On/Off switch
Automatic safety overload protection system
Dimension:130(W) x150(D) x84(H)mm
Weight: 1700g
Feature of 90-108E(For Dental Clinic) Dental Lab Micromotor Handpiece
Max Speed: 35000rpm
Rated Power: 65W
Torque: 280gf.cm
Variable speed control by hand dial or foot pedal
On/Off switch
Dimension: 95(W) x124(D) x68(H)mm
Weight: 1300g